The range of shut-off Danfoss valves includes ball valves, high-pressure ball valves, diaphragm valves, and traditional shut-off valves, available in angled and straight versions and stainless steel versions. Shut-off valves for use in liquid, suction, and hot gas pipelines in all refrigeration and air conditioning systems with refrigerants from groups: HCFC, HFC, R717 (ammonia), and R744 (CO2).

Parameters

Performance

All

All

All

All

All

GBC

GBC

Danfoss
Refrigerant:
R22, R134a, R290, R32, R404A, R407A, R407C, R407F, R410A, R448A, R449A, R450A, R452A, R452B, R454A, R454B, R454C, R455A, R507, R513A, R1234yf
Inlet connection type:
Soldered
Maximum working pressure [bar]:
45 - 49
Service valve:
None, Schrader valve
GBCH

GBCH

Danfoss
Refrigerant:
R744 (CO₂)
Inlet connection type:
Soldered, Welded
Maximum working pressure [bar]:
75 - 90
Service valve:
None, Schrader valve
GBCT

GBCT

Danfoss
Refrigerant:
R744 (CO₂)
Inlet connection type:
Soldered
Maximum working pressure [bar]:
140
Service valve:
None, Schrader valve
BML

BML

Danfoss
Refrigerant:
R134a, R290, R450A, R513A, R600a, R1234yf, R1234ze
Inlet connection type:
Flare, Soldered
Maximum working pressure [bar]:
28
Service valve:
None
SVA

SVA

Danfoss
Refrigerant:
R22, R134a, R290, R32, R404A, R407A, R407C, R407F, R410A, R448A, R449A, R450A, R452A, R452B, R454A, R454B, R454C, R455A, R513A, R515B, R600a, R717 (ammonia), R744 (CO₂), R1234yf, R1234ze
Inlet connection type:
Flare, Soldered, Welded, Thread
Maximum working pressure [bar]:
52
Service valve:
None
SCA

SCA

Danfoss
Refrigerant:
R22, R134a, R290, R32, R404A, R407A, R407C, R407F, R410A, R448A, R449A, R450A, R452A, R452B, R454A, R454B, R454C, R455A, R513A, R515B, R600a, R717 (ammonia), R744 (CO₂), R1234yf
Inlet connection type:
Welded
Maximum working pressure [bar]:
52
Service valve:
None

The range of shut-off Danfoss valves includes ball valves, high-pressure ball valves, diaphragm valves, and traditional shut-off valves, available in angled and straight versions and stainless steel versions. Shut-off valves for use in liquid, suction, and hot gas pipelines in all refrigeration and air conditioning systems with refrigerants from groups: HCFC, HFC, R717 (ammonia), and R744 (CO2).

Manually operated ball shut-off valves, adapted to the flow in both directions, are used in liquid, suction, and hot pipelines in all refrigeration and air conditioning systems with fluorinated refrigerants. The stem construction, resistant to damage, prevents liquid from becoming trapped inside the valve. The valve socket made of modified Teflon ensures maximum tightness and long life. Bi-directional ball valves ensure full flow with minimal pressure drop. Special high-pressure versions are selected and tested for use with CO2 refrigerants.

Diaphragm shut-off valves designed for installation in liquid, suction, and hot gas pipelines in traditional refrigeration systems. Equipped with stainless steel membranes, they provide long service life. Adapted to work with refrigerants from groups: HCFC, HFC, and HC.

Due to frequent changes and updates, presented data are provided on illustrative basis only. All materials contained on this website are protected by copyright and their use, copying and publishing in any form is prohibited without the written consent of Elektronika SA. Please read the full Terms of Use.

Sales of equipment

We are a direct importer, representative and authorized distributor of the world's leading refrigeration and air conditioning manufacturers. The main activity of the company is wholesale and distribution of HVACR equipment and accessories, including heat pumps and chillers, through its own network of branches.

Check our offer

Technical support

We actively support our HVACR Installers and Designers. We organize product trainings; provide assistance and technical advice to refrigeration and air conditioning engineers at every stage of the investment realization. Hundreds of successful investments confirm our competence and extensive experience.

Check our offer

Investment processes

Our organizational structures include Investment Implementation Departments, which, based on the skills of engineers and designers, in cooperation with installation companies from the investment area, are able to design and implement the most modern cooling, freezing and air conditioning units.

Check our offer

Cookies information

This website uses cookies to improve the quality of the services provided. It also uses the Third-Party cookies, they provide tools and solutions that improve the ergonomics and functionality of the website, such as video playback, website usage analytics and marketing content customization.

By clicking accept, you agree to use cookies, as outlined in our Cookie Policy